Loading...
ORD 2004-08 - Amend Title 9 Building Regulations 03-23-2004ORDINANCE NO. 2004-08 AN ORDINANCE AMENDING TITLE 9, "BUILDINGS AND BUILDING REGULATIONS," OF THE HUNTSVILLE, TEXAS, MUNICIPAL CODE TO ADD LANGUAGE TO PROVIDE FOR AN AMENDMENT TO THE INTERNATIONAL RESIDENTIAL CODE, 2000 EDITION, PREVIOUSLY ADOPTED BY REFERENCE AS THE RESIDENTIAL CODE OF THE CITY. BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF HUNTSVILLE, TEXAS, that: Section 1: Section 9.02.09, entitled "International residential code" of Title 9, 'Buildings and Building Regulations," of the Huntsville, Texas, Municipal Code is hereby amended to add the following subsection: 13. R309.2 is hereby amended to read: R309.2 Separation Required. The garage shall be separated from the residence and its attic area by not less than % inch (12.7 mm) gypsum board from the floor to the roof deck applied to the garage side or from the floor to the ceiling of the garage with the garage ceiling being covered with not less than 5/8 inch fire code gypsum board. Where the separation is a floor /ceiling assembly, the structure supporting the separation shall also be protected by not less than 5/8 inch fire code gypsum board as equivalent. Section 2: This ordinance shall take effect immediately from and after the date of its passage. PASSED AND APPROVED this the 23rd day of March 2004. ATTEST: Danna Welter, City Secretary WACITY- SEC\AGN- MTS\CATCW UP MINUTES \03 - 23.04 \08 - AMEND - TITLE- 9- ORD.DOC CITY OF HUNTSVILL XAS Karl Davidson, Mayor APPROVED AS TO FORM: Thomas A. Leepe'r',thtykttorney PAGE 1